CVE-2013-5021

Critical

Description

Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.

SeverityCritical
CVSS9.3
Exploit probability—
ProductNi Labview
PublishedAug 6, 2013
First seenAug 6, 2013

How to fix

Sources list no fixed version or patch link for this vulnerability.

Affected products

ProductAffected versionsFixed in
ni labviewv ≤ 2012—
ni labwindowsv ≤ 2012—
ni measurementstudiov ≤ 2013—
ni teststandv ≤ 2012—
abb datamanager1.0.0, 6.3.6—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.

CVE-2013-5021 · Ni Labview · Dark Radar