Description

An issue was discovered in eClinicalWorks healow@work 8.0 build 8. This is a blind SQL injection within the EmployeePortalServlet, which can be exploited by un-authenticated users via an HTTP POST request and which can be used to dump database data out to a malicious server, using an out-of-band technique, such as select_loadfile(). The vulnerability affects the EmployeePortalServlet page and the following parameter: employer.

SeverityHigh
CVSS7.5
Exploit probability—
ProductEclinicalworks Patient Portal
PublishedJan 27, 2017
First seenJan 27, 2017

How to fix

Sources list no fixed version or patch link for this vulnerability.

Affected products

ProductAffected versionsFixed in
eclinicalworks patient_portal8.0—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan