CVE-2017-7899

Critical

Description

An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available for unauthorized retrieval.

SeverityCritical
CVSS9.8
Exploit probability—
ProductRockwellautomation 1763-l16awa Series A
PublishedJun 30, 2017
First seenJun 30, 2017

How to fix

Sources list no fixed version or patch link for this vulnerability.

Affected products

ProductAffected versionsFixed in
rockwellautomation 1763-l16awa_series_av ≤ 16.000—
rockwellautomation 1763-l16awa_series_bv ≤ 16.000—
rockwellautomation 1763-l16bbb_series_av ≤ 16.000—
rockwellautomation 1763-l16bbb_series_bv ≤ 16.000—
rockwellautomation 1763-l16bwa_series_av ≤ 16.000—
rockwellautomation 1763-l16bwa_series_bv ≤ 16.000—
rockwellautomation 1763-l16dwd_series_av ≤ 16.000—
rockwellautomation 1763-l16dwd_series_bv ≤ 16.000—
rockwellautomation 1766-l32awa_series_av ≤ 16.000—
rockwellautomation 1766-l32awa_series_bv ≤ 16.000—
rockwellautomation 1766-l32awaa_series_av ≤ 16.000—
rockwellautomation 1766-l32awaa_series_bv ≤ 16.000—
rockwellautomation 1766-l32bwa_series_av ≤ 16.000—
rockwellautomation 1766-l32bwa_series_bv ≤ 16.000—
rockwellautomation 1766-l32bwaa_series_av ≤ 16.000—
rockwellautomation 1766-l32bwaa_series_bv ≤ 16.000—
rockwellautomation 1766-l32bxb_series_av ≤ 16.000—
rockwellautomation 1766-l32bxb_series_bv ≤ 16.000—
rockwellautomation 1766-l32bxba_series_av ≤ 16.000—
rockwellautomation 1766-l32bxba_series_bv ≤ 16.000—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.