CVE-2018-11457

High

Description

A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known.

SeverityHigh
CVSS8.1
Exploit probability—
ProductSiemens Sinumerik 828d V4.7 Firmware
PublishedDec 12, 2018
First seenDec 12, 2018
Weakness typeCWE-122CWE-122

How to fix

Sources list no fixed version or patch link for this vulnerability.

Affected products

ProductAffected versionsFixed in
siemens sinumerik_828d_v4.7_firmwarev ≤ 4.7—
siemens sinumerik_840d_sl_v4.7_firmwarev ≤ 4.7—
siemens sinumerik_840d_sl_v4.8_firmwarev ≤ 4.8—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.