CVE-2018-11460

High

Description

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

SeverityHigh
CVSS7.8
Exploit probability—
ProductSiemens Sinumerik 808d V4.7 Firmware
PublishedDec 12, 2018
First seenDec 12, 2018
Weakness typeCWE-693CWE-693

How to fix

Sources list no fixed version or patch link for this vulnerability.

Affected products

ProductAffected versionsFixed in
siemens sinumerik_808d_v4.7_firmwareNo range specified—
siemens sinumerik_808d_v4.8_firmwareNo range specified—
siemens sinumerik_828d_v4.7_firmwarev ≤ 4.7—
siemens sinumerik_840d_sl_v4.7_firmwarev ≤ 4.7—
siemens sinumerik_840d_sl_v4.8_firmwarev ≤ 4.8—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.