CVE-2018-13807

High

Description

A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions). The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The device will automatically reboot, impacting network availability for other devices. An attacker must have network access to port 443/tcp to exploit the vulnerability. Neither valid credentials nor interaction by a legitimate user is required to exploit the vulnerability. There is no confidentiality or integrity impact, only availability is temporarily impacted. This vulnerability could be triggered by publicly available tools.

SeverityHigh
CVSS8.6
Exploit probability—
ProductSiemens Scalance X408 Firmware
PublishedSep 12, 2018
First seenSep 12, 2018

How to fix

Update
  • siemens scalance_x408_firmware4.0.0 or later
  • siemens scalance_x300_firmware4.0.0 or later

Affected products

ProductAffected versionsFixed in
siemens scalance_x408_firmwarev < 4.0.04.0.0
siemens scalance_x300_firmwarev < 4.0.04.0.0
siemens scalance_x414_firmwareNo range specified—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.