CVE-2018-13814

High

Description

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

SeverityHigh
CVSS8.8
Exploit probability—
ProductSiemens Simatic Hmi Comfort Panels Firmware
PublishedDec 13, 2018
First seenDec 13, 2018
Weakness typeCWE-113CWE-113

How to fix

Update
  • siemens simatic_hmi_comfort_panels_firmware14.0 or later
  • siemens simatic_hmi_comfort_outdoor_panels_firmware14.0 or later
  • siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware14.0 or later
  • siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware14.0 or later
  • siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware14.0 or later
  • siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware14.0 or later
  • siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware14.0 or later
  • siemens simatic_wincc_\(tia_portal\)14.0 or later
  • siemens simatic_wincc_runtime14.0 or later

Affected products

ProductAffected versionsFixed in
siemens simatic_hmi_comfort_panels_firmwarev < 14.014.0
siemens simatic_hmi_comfort_outdoor_panels_firmwarev < 14.014.0
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmwarev < 14.014.0
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmwarev < 14.014.0
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmwarev < 14.014.0
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmwarev < 14.014.0
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmwarev < 14.014.0
siemens simatic_wincc_\(tia_portal\)v < 14.014.0
siemens simatic_wincc_runtimev < 14.014.0
siemens simatic_hmi_tp_firmwareNo range specified—
siemens simatic_hmi_mp_firmwareNo range specified—
siemens simatic_hmi_op_firmwareNo range specified—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.