CVE-2018-7782

High

Description

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text.

SeverityHigh
CVSS8.8
Exploit probability—
ProductSchneider-electric Imps110-1 Firmware
PublishedJul 3, 2018
First seenJul 3, 2018

How to fix

Update
  • schneider-electric imps110-1_firmware3.29.69 or later
  • schneider-electric imps110-1e_firmware3.29.69 or later
  • schneider-electric imps110-1er_firmware3.29.69 or later
  • schneider-electric ibps110-1er_firmware3.29.69 or later
  • schneider-electric imp1110-1_firmware3.29.69 or later
  • schneider-electric imp1110-1e_firmware3.29.69 or later
  • schneider-electric imp1110-1er_firmware3.29.69 or later
  • schneider-electric ibp1110-1er_firmware3.29.69 or later
  • schneider-electric imp219-1_firmware3.29.69 or later
  • schneider-electric imp219-1e_firmware3.29.69 or later
  • schneider-electric imp219-1er_firmware3.29.69 or later
  • schneider-electric ibp219-1er_firmware3.29.69 or later

Affected products

ProductAffected versionsFixed in
schneider-electric imps110-1_firmwarev < 3.29.693.29.69
schneider-electric imps110-1e_firmwarev < 3.29.693.29.69
schneider-electric imps110-1er_firmwarev < 3.29.693.29.69
schneider-electric ibps110-1er_firmwarev < 3.29.693.29.69
schneider-electric imp1110-1_firmwarev < 3.29.693.29.69
schneider-electric imp1110-1e_firmwarev < 3.29.693.29.69
schneider-electric imp1110-1er_firmwarev < 3.29.693.29.69
schneider-electric ibp1110-1er_firmwarev < 3.29.693.29.69
schneider-electric imp219-1_firmwarev < 3.29.693.29.69
schneider-electric imp219-1e_firmwarev < 3.29.693.29.69
schneider-electric imp219-1er_firmwarev < 3.29.693.29.69
schneider-electric ibp219-1er_firmwarev < 3.29.693.29.69
schneider-electric imp319-1_firmwarev < 3.29.693.29.69
schneider-electric imp319-1e_firmwarev < 3.29.693.29.69
schneider-electric imp319-1er_firmwarev < 3.29.693.29.69
schneider-electric ibp319-1er_firmwarev < 3.29.693.29.69
schneider-electric imp519-1_firmwarev < 3.29.693.29.69
schneider-electric imp519-1e_firmwarev < 3.29.693.29.69
schneider-electric imp519-1er_firmwarev < 3.29.693.29.69
schneider-electric ibp519-1er_firmwarev < 3.29.693.29.69

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.