CVE-2019-6575

High

Description

A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.

SeverityHigh
CVSS7.5
Exploit probability—
ProductSiemens Simatic Cp443-1 Opc Ua Firmware
PublishedApr 17, 2019
First seenApr 17, 2019
Weakness typeCWE-248CWE-248

How to fix

Update
  • siemens simatic_et_200_open_controller_cpu_1515sp_pc2_firmware2.7 or later
  • siemens simatic_wincc_oa3.15-p018 or later
  • siemens sinec-nms1.0 or later
  • siemens sinumerik_opc_ua_server2.1 or later
  • siemens telecontrol_server_basic3.1.1 or later
  • siemens simatic_hmi_comfort_outdoor_panels_firmware15.1 or later
  • siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware15.1 or later
  • siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware15.1 or later
  • siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware15.1 or later
  • siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware15.1 or later
  • siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware15.1 or later

Affected products

ProductAffected versionsFixed in
siemens simatic_cp443-1_opc_ua_firmwareNo range specified—
siemens simatic_et_200_open_controller_cpu_1515sp_pc2_firmwarev < 2.72.7
siemens simatic_ipc_diagmonitor_firmwareNo range specified—
siemens simatic_net_pc_software_firmwareNo range specified—
siemens simatic_rf188c_firmwareNo range specified—
siemens simatic_rf600r_firmwareNo range specified—
siemens simatic_s7-1500_firmwarev ≤ 2.5—
siemens opc_unified_architectureNo range specified—
siemens simatic_s7-1500_software_controllerv ≤ 2.5—
siemens simatic_wincc_oav < 3.15-p0183.15-p018
siemens simatic_wincc_runtime_advancedNo range specified—
siemens simatic_wincc_runtime_comfortNo range specified—
siemens simatic_wincc_runtime_hsp_comfortNo range specified—
siemens simatic_wincc_runtime_mobileNo range specified—
siemens sinec-nmsv < 1.0, 1.01.0
siemens sinema_serverNo range specified—
siemens sinumerik_opc_ua_serverv < 2.12.1
siemens telecontrol_server_basicv < 3.1.13.1.1
siemens simatic_s7-1500f_firmwarev ≤ 2.5—
siemens simatic_s7-1500s_firmwarev ≤ 2.5—
siemens simatic_s7-1500t_firmwarev ≤ 2.5—
siemens simatic_hmi_comfort_outdoor_panels_firmwarev < 15.1, 15.115.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmwarev < 15.1, 15.115.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmwarev < 15.1, 15.115.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmwarev < 15.1, 15.115.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmwarev < 15.1, 15.115.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmwarev < 15.1, 15.115.1