CVE-2020-10270

Critical

Description

Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.

SeverityCritical
CVSS9.8
Exploit probability—
ProductAliasrobotics Mir100 Firmware
PublishedJun 24, 2020
First seenJun 24, 2020

How to fix

Sources list no fixed version or patch link for this vulnerability.

Affected products

ProductAffected versionsFixed in
aliasrobotics mir100_firmwarev ≤ 2.8.1.1—
aliasrobotics mir200_firmwarev ≤ 2.8.1.1—
aliasrobotics mir250_firmwarev ≤ 2.8.1.1—
aliasrobotics mir500_firmwarev ≤ 2.8.1.1—
aliasrobotics mir1000_firmwarev ≤ 2.8.1.1—
mobile-industrial-robotics er200_firmwarev ≤ 2.8.1.1—
enabled-robotics er-lite_firmwarev ≤ 2.8.1.1—
enabled-robotics er-flex_firmwarev ≤ 2.8.1.1—
enabled-robotics er-one_firmwarev ≤ 2.8.1.1—
uvd-robots uvd_robots_firmwarev ≤ 2.8.1.1—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.