CVE-2020-13987

High

Description

An issue was discovered in Contiki through 3.0. An Out-of-Bounds Read vulnerability exists in the uIP TCP/IP Stack component when calculating the checksums for IP packets in upper_layer_chksum in net/ipv4/uip.c.

SeverityHigh
CVSS7.5
Exploit probability—
ProductUip
PublishedDec 11, 2020
First seenDec 11, 2020

How to fix

Update
  • siemens sentron_3va_com100_firmware4.4.1 or later
  • siemens sentron_3va_com800_firmware4.4.1 or later
  • siemens sentron_pac3200_firmware2.4.7 or later
  • siemens sentron_pac4200_firmware2.3.0 or later

Affected products

ProductAffected versionsFixed in
uip_project uipv ≤ 1.0—
open-iscsi_project open-iscsiv ≤ 2.1.12—
siemens sentron_3va_com100_firmwarev < 4.4.14.4.1
siemens sentron_3va_com800_firmwarev < 4.4.14.4.1
siemens sentron_pac3200_firmwarev < 2.4.72.4.7
siemens sentron_pac4200_firmwarev < 2.3.02.3.0

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.