CVE-2021-20587

High

Description

Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior, and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition on the software products, and possibly to execute a malicious code on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.

SeverityHigh
CVSS7.5
Exploit probability—
ProductMitsubishielectric Data Transfer
PublishedFeb 19, 2021
First seenFeb 19, 2021
Weakness typeCWE-122CWE-122

How to fix

Affected products

ProductAffected versionsFixed in
mitsubishielectric data_transferv ≤ 3.44w—
mitsubishielectric c_controller_module_setting_and_monitoring_toolNo range specified—
mitsubishielectric cpu_module_logging_configuration_toolv ≤ 1.112r—
mitsubishielectric cw_configuratorv ≤ 1.011m—
mitsubishielectric ezsocketNo range specified—
mitsubishielectric fr_configuratorNo range specified—
mitsubishielectric fr_configurator_sw3No range specified—
mitsubishielectric fr_configurator2v ≤ 1.24a—
mitsubishielectric gt_designer3v ≤ 1.250l—
mitsubishielectric gt_softgot1000v ≤ 3.245f—
mitsubishielectric gt_softgot2000v ≤ 1.250l—
mitsubishielectric gx_configurator-dpv ≤ 7.14q—
mitsubishielectric gx_configurator-qpNo range specified—
mitsubishielectric gx_developerv ≤ 8.506c—
mitsubishielectric gx_explorerNo range specified—
mitsubishielectric gx_iec_developerNo range specified—
mitsubishielectric gx_logviewerv ≤ 1.115u—
mitsubishielectric gx_remoteservice-iNo range specified—
mitsubishielectric gx_works2v ≤ 1.597x—
mitsubishielectric gx_works3v ≤ 1.070y—
mitsubishielectric iq_monozukuri_andonNo range specified—
mitsubishielectric iq_monozukuri_process_remote_monitoringNo range specified—
mitsubishielectric m_commdtm-hartNo range specified—
mitsubishielectric m_commdtm-io-linkNo range specified—
mitsubishielectric melfa-worksv ≤ 4.4—
mitsubishielectric melsec_wincpu_setting_utilityNo range specified—
mitsubishielectric melsoft_em_software_development_kitNo range specified—
mitsubishielectric melsoft_navigatorv ≤ 2.74c—
mitsubishielectric mh11_settingtool_version2v ≤ 2.004e—
mitsubishielectric mi_configuratorNo range specified—
mitsubishielectric mt_works2v ≤ 1.167z—
mitsubishielectric mx_componentv ≤ 5.001b—
mitsubishielectric network_interface_board_cc-linkNo range specified—
mitsubishielectric network_interface_board_cc_ie_control_utilityNo range specified—
mitsubishielectric network_interface_board_cc_ie_field_utilityNo range specified—
mitsubishielectric network_interface_board_mneth_utilityNo range specified—
mitsubishielectric px_developerv ≤ 1.53f—
mitsubishielectric rt_toolbox2v ≤ 3.73b—
mitsubishielectric rt_toolbox3v ≤ 1.82l—
mitsubishielectric setting\/monitoring_tools_for_the_c_controller_moduleNo range specified—
mitsubishielectric slmp_data_collectorv ≤ 1.04e—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.