CVE-2021-31892

High

Description

A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario.

SeverityHigh
CVSS7.4
Exploit probability—
ProductSiemens Sinumerik Analyse Mycondition Firmware
PublishedJul 13, 2021
First seenJul 13, 2021
Weakness typeCWE-295CWE-295

How to fix

Update
  • siemens sinumerik_integrate_client_firmware2.00.18, 3.00.18, 4.00.18 or later
  • siemens sinumerik_operate_firmware4.8 or later

Affected products

ProductAffected versionsFixed in
siemens sinumerik_analyse_mycondition_firmwareNo range specified—
siemens sinumerik_analyze_myperformance_firmwareNo range specified—
siemens sinumerik_integrate_client_firmware2.00.12 ≤ v < 2.00.18, 3.00.12 ≤ v < 3.00.18, 4.00.15 ≤ v < 4.00.182.00.18, 3.00.18, 4.00.18
siemens sinumerik_integrate_for_production_firmwarev ≤ 4.1, 5.1—
siemens sinumerik_manage_mymachines_firmwareNo range specified—
siemens sinumerik_manage_myprograms_firmwareNo range specified—
siemens sinumerik_manage_myresources_firmwareNo range specified—
siemens sinumerik_manage_mytools_firmwareNo range specified—
siemens sinumerik_operate_firmwarev < 4.8, 4.8, 4.93, 4.944.8
siemens sinumerik_optimize_myprogramming_firmwareNo range specified—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management