CVE-2021-32025

High

Description

An elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Platform version(s) 6.4.0 to 7.0, QNX Momentics all 6.3.x versions, QNX OS for Safety versions 1.0.0 to 1.0.2, QNX OS for Safety versions 2.0.0 to 2.0.1, QNX for Medical versions 1.0.0 to 1.1.1, and QNX OS for Medical version 2.0.0 could allow an attacker to potentially access data, modify behavior, or permanently crash the system.

SeverityHigh
CVSS8.1
Exploit probability—
ProductBlackberry Qnx Momentics
PublishedMar 10, 2022
First seenMar 10, 2022
Weakness typeCWE-368CWE-368

How to fix

Update
  • blackberry qnx_os_for_medical1.1.2 or later
  • blackberry qnx_os_for_safety1.0.3, 2.0.2 or later

Affected products

ProductAffected versionsFixed in
blackberry qnx_momentics6.3.0, 6.3.2—
blackberry qnx_software_development_platform6.4.0 ≤ v ≤ 7.0—
blackberry qnx_os_for_medical1.0 ≤ v < 1.1.2, 2.0.01.1.2
blackberry qnx_os_for_safety1.0.0 ≤ v < 1.0.3, 2.0.0 ≤ v < 2.0.21.0.3, 2.0.2

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan