CVE-2022-32985

Critical

Description

libnx_apl.so on Nexans FTTO GigaSwitch before 6.02N and 7.x before 7.02 implements a Backdoor Account for SSH logins on port 50200 or 50201.

SeverityCritical
CVSS9.8
Exploit probability—
ProductNexans Gigaswitch 641 Desk V5 Sfp-vi Firmware
PublishedJul 17, 2022
First seenJul 17, 2022

How to fix

Update
  • nexans gigaswitch_641_desk_v5_sfp-vi_firmware6.02n, 7.02 or later
  • nexans gigaswitch_642_desk_v5_sfp-2vi_firmware6.02n, 7.02 or later
  • nexans gigaswitch_v5_2tp\(pd-f\+\)_sfp-vi_54vdc_firmware6.02n, 7.02 or later
  • nexans gigaswitch_v5_2tp\(pse\+\)_sfp-vi_54vdc_firmware6.02n, 7.02 or later
  • nexans gigaswitch_v5_2tp_sfp-vi_54vdc_firmware6.02n, 7.02 or later
  • nexans gigaswitch_v5_sfp-2vi_230vac_firmware6.02n, 7.02 or later
  • nexans gigaswitch_v5_tp\(pse\+\)_sfp-2vi_54vdc_firmware6.02n, 7.02 or later
  • nexans gigaswitch_v5_tp\(pse\+\)_sfp-2vi_54vdc_ind_firmware6.02n, 7.02 or later
  • nexans gigaswitch_v5_tp\(pse\+\)_sfp-2vi_54vdc_med_firmware6.02n, 7.02 or later
  • nexans gigaswitch_v5_tp_sfp-2vi_54vdc_firmware6.02n, 7.02 or later
  • nexans gigaswitch_v5_tp_sfp-2vi_54vdc_ind_firmware6.02n, 7.02 or later
  • nexans gigaswitch_v5_tp_sfp-2vi_54vdc_med_firmware6.02n, 7.02 or later

Affected products

ProductAffected versionsFixed in
nexans gigaswitch_641_desk_v5_sfp-vi_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_642_desk_v5_sfp-2vi_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_v5_2tp\(pd-f\+\)_sfp-vi_54vdc_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_v5_2tp\(pse\+\)_sfp-vi_54vdc_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_v5_2tp_sfp-vi_54vdc_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_v5_sfp-2vi_230vac_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_v5_tp\(pse\+\)_sfp-2vi_54vdc_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_v5_tp\(pse\+\)_sfp-2vi_54vdc_ind_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_v5_tp\(pse\+\)_sfp-2vi_54vdc_med_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_v5_tp_sfp-2vi_54vdc_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_v5_tp_sfp-2vi_54vdc_ind_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_v5_tp_sfp-2vi_54vdc_med_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02
nexans gigaswitch_v5_tp_sfp-vi_230vac_firmwarev < 6.02n, 7.0 ≤ v < 7.026.02n, 7.02

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.