CVE-2022-42784

High

Description

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.

SeverityHigh
CVSS7.6
Exploit probability—
ProductSiemens 6ed1052-1md08-0ba1 Firmware
PublishedDec 12, 2023
First seenDec 12, 2023
Weakness typeCWE-1319CWE-1319

How to fix

Sources list no fixed version or patch link for this vulnerability.

Affected products

ProductAffected versionsFixed in
siemens 6ed1052-1md08-0ba1_firmwarev ≤ 8.3—
siemens 6ed1052-2md08-0ba1_firmwarev ≤ 8.3—
siemens 6ed1052-1cc08-0ba1_firmwarev ≤ 8.3—
siemens 6ed1052-2cc08-0ba1_firmwarev ≤ 8.3—
siemens 6ed1052-1hb08-0ba1_firmwarev ≤ 8.3—
siemens 6ed1052-2hb08-0ba1_firmwarev ≤ 8.3—
siemens 6ed1052-1fb08-0ba1_firmwarev ≤ 8.3—
siemens 6ed1052-2fb08-0ba1_firmwarev ≤ 8.3—
siemens 6ag1052-1md08-7ba1_firmwarev ≤ 8.3—
siemens 6ag1052-2md08-7ba1_firmwarev ≤ 8.3—
siemens 6ag1052-1cc08-7ba1_firmwarev ≤ 8.3—
siemens 6ag1052-2cc08-7ba1_firmwarev ≤ 8.3—
siemens 6ag1052-1hb08-7ba1_firmwarev ≤ 8.3—
siemens 6ag1052-2hb08-7ba1_firmwarev ≤ 8.3—
siemens 6ag1052-1fb08-7ba1_firmwarev ≤ 8.3—
siemens 6ag1052-2fb08-7ba1_firmwarev ≤ 8.3—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan