CVE-2023-28827

Medium

Description

A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers. This could allow a remote attacker to cause a denial of service condition in the system.

SeverityMedium
CVSS5.9
Exploit probability—
ProductSIMATIC CP 1242-7 V2 (incl. SIPLUS variants)
PublishedSep 10, 2024
First seenSep 10, 2024

How to fix

Update
  • Siemens SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)V3.5.20 or later
  • Siemens SIMATIC CP 1243-1 (incl. SIPLUS variants)V3.5.20 or later
  • Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)V3.5.20 or later
  • Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)V3.5.20 or later
  • Siemens SIMATIC CP 1243-7 LTEV3.5.20 or later
  • Siemens SIMATIC CP 1243-8 IRCV3.5.20 or later
  • Siemens SIPLUS TIM 1531 IRCV2.4.8 or later
  • Siemens TIM 1531 IRCV2.4.8 or later

Affected products

ProductAffected versionsFixed in
Siemens SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)v < V3.5.20V3.5.20
Siemens SIMATIC CP 1243-1 (incl. SIPLUS variants)v < V3.5.20V3.5.20
Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)v < V3.5.20V3.5.20
Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)v < V3.5.20V3.5.20
Siemens SIMATIC CP 1243-7 LTEv < V3.5.20V3.5.20
Siemens SIMATIC CP 1243-8 IRCv < V3.5.20V3.5.20
Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants)No range specified—
Siemens SIMATIC IPC DiagBase0—
Siemens SIMATIC IPC DiagMonitorNo range specified—
Siemens SIMATIC WinCC Runtime AdvancedNo range specified—
Siemens SIPLUS TIM 1531 IRCv < V2.4.8V2.4.8
Siemens TIM 1531 IRCv < V2.4.8V2.4.8

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.