CVE-2023-29114
Description
System logs could be accessed through web management application due to a lack of access control. An attacker can obtain the following sensitive information: • Wi-Fi access point credentials to which the EV charger can connect. • APN web address and credentials. • IPSEC credentials. • Web interface access credentials for user and admin accounts. • JuiceBox system components (software installed, model, firmware version, etc.). • C2G configuration details. • Internal IP addresses. • OTA firmware update configurations (DNS servers). All the credentials are stored in logs in an unencrypted plaintext format.
How to fix
- Enel X JuiceBox Pro 3.0 22kW Cellular2.1.1.0_JB3VU096A or later
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Enel X JuiceBox Pro 3.0 22kW Cellular | v < 2.1.1.0_JB3VU096A | 2.1.1.0_JB3VU096A |