CVE-2024-2893

High

Description

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

SeverityHigh
CVSS8.8
Exploit probability—
ProductTenda Ac7 Firmware
PublishedMar 26, 2024
First seenMar 26, 2024
Weakness typeCWE-121CWE-121

How to fix

Sources list no fixed version or patch link for this vulnerability.

Affected products

ProductAffected versionsFixed in
tenda ac7_firmware15.03.06.44—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan