CVE-2024-30212
Description
If a SCSI READ(10) command is initiated via USB using the largest LBA (0xFFFFFFFF) with it's default block size of 512 and a count of 1, the first 512 byte of the 0x80000000 memory area is returned to the user. If the block count is increased, the full RAM can be exposed. The same method works to write to this memory area. If RAM contains pointers, those can be - depending on the application - overwritten to return data from any other offset including Progam and Boot Flash.
How to fix
- Microchip MPLAB® Harmony 3 Core Module3.13.4 or later
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Microchip MPLAB® Harmony 3 Core Module | 3.0.0 ≤ v < 3.13.4 | 3.13.4 |
Check your version
Choose the product and enter the version you run to see whether it falls in the affected range.