CVE-2024-53648

Medium

Description

A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions < V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V10.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.90), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.90), SIPROTEC 5 7SK82 (CP100) (All versions < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.90), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions < V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device.

SeverityMedium
CVSS6.8
Exploit probability—
ProductSIPROTEC 5 6MD84 (CP300)
PublishedFeb 11, 2025
First seenFeb 11, 2025
Weakness typeCWE-489CWE-489

How to fix

Update
  • Siemens SIPROTEC 5 6MD84 (CP300)V9.90 or later
  • Siemens SIPROTEC 5 6MD85 (CP300)V9.90 or later
  • Siemens SIPROTEC 5 6MD86 (CP300)V9.90 or later
  • Siemens SIPROTEC 5 6MD89 (CP300)V9.90 or later
  • Siemens SIPROTEC 5 6MU85 (CP300)V9.90 or later
  • Siemens SIPROTEC 5 7KE85 (CP300)V10.0 or later
  • Siemens SIPROTEC 5 7SA82 (CP100)V8.90 or later
  • Siemens SIPROTEC 5 7SA82 (CP150)V9.90 or later
  • Siemens SIPROTEC 5 7SA86 (CP300)V9.90 or later
  • Siemens SIPROTEC 5 7SA87 (CP300)V9.90 or later
  • Siemens SIPROTEC 5 7SD82 (CP100)V8.90 or later
  • Siemens SIPROTEC 5 7SD82 (CP150)V9.90 or later

Affected products

ProductAffected versionsFixed in
Siemens SIPROTEC 5 6MD84 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 6MD85 (CP200)0—
Siemens SIPROTEC 5 6MD85 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 6MD86 (CP200)0—
Siemens SIPROTEC 5 6MD86 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 6MD89 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 6MU85 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7KE85 (CP200)0—
Siemens SIPROTEC 5 7KE85 (CP300)v < V10.0V10.0
Siemens SIPROTEC 5 7SA82 (CP100)v < V8.90V8.90
Siemens SIPROTEC 5 7SA82 (CP150)v < V9.90V9.90
Siemens SIPROTEC 5 7SA86 (CP200)0—
Siemens SIPROTEC 5 7SA86 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7SA87 (CP200)0—
Siemens SIPROTEC 5 7SA87 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7SD82 (CP100)v < V8.90V8.90
Siemens SIPROTEC 5 7SD82 (CP150)v < V9.90V9.90
Siemens SIPROTEC 5 7SD86 (CP200)0—
Siemens SIPROTEC 5 7SD86 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7SD87 (CP200)0—
Siemens SIPROTEC 5 7SD87 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7SJ81 (CP100)v < V8.90V8.90
Siemens SIPROTEC 5 7SJ81 (CP150)v < V9.90V9.90
Siemens SIPROTEC 5 7SJ82 (CP100)v < V8.90V8.90
Siemens SIPROTEC 5 7SJ82 (CP150)v < V9.90V9.90
Siemens SIPROTEC 5 7SJ85 (CP200)0—
Siemens SIPROTEC 5 7SJ85 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7SJ86 (CP200)0—
Siemens SIPROTEC 5 7SJ86 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7SK82 (CP100)v < V8.90V8.90
Siemens SIPROTEC 5 7SK82 (CP150)v < V9.90V9.90
Siemens SIPROTEC 5 7SK85 (CP200)0—
Siemens SIPROTEC 5 7SK85 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7SL82 (CP100)v < V8.90V8.90
Siemens SIPROTEC 5 7SL82 (CP150)v < V9.90V9.90
Siemens SIPROTEC 5 7SL86 (CP200)0—
Siemens SIPROTEC 5 7SL86 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7SL87 (CP200)0—
Siemens SIPROTEC 5 7SL87 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7SS85 (CP200)0—
Siemens SIPROTEC 5 7SS85 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7ST85 (CP200)0—
Siemens SIPROTEC 5 7ST85 (CP300)v < V10.0V10.0
Siemens SIPROTEC 5 7ST86 (CP300)v < V10.0V10.0
Siemens SIPROTEC 5 7SX82 (CP150)v < V9.90V9.90
Siemens SIPROTEC 5 7SX85 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7SY82 (CP150)v < V9.90V9.90
Siemens SIPROTEC 5 7UM85 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7UT82 (CP100)v < V8.90V8.90
Siemens SIPROTEC 5 7UT82 (CP150)v < V9.90V9.90
Siemens SIPROTEC 5 7UT85 (CP200)0—
Siemens SIPROTEC 5 7UT85 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7UT86 (CP200)0—
Siemens SIPROTEC 5 7UT86 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7UT87 (CP200)0—
Siemens SIPROTEC 5 7UT87 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7VE85 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7VK87 (CP200)0—
Siemens SIPROTEC 5 7VK87 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 7VU85 (CP300)v < V9.90V9.90
Siemens SIPROTEC 5 Compact 7SX800 (CP050)v < V9.90V9.90

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.