CVE-2024-8957

HighActively exploited (CISA KEV)

Description

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.

SeverityHigh
CVSS7.2
Exploit probability—
ProductPTZOptics PT30X-SDI/NDI Cameras
PublishedSep 17, 2024
First seenSep 17, 2024
Added to KEVNov 4, 2024

How to fix

CISA required action

Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

CISA due date: Nov 25, 2024
Update
  • ptzoptics pt30x-sdi_firmware6.3.40 or later
  • ptzoptics pt30x-ndi-xx-g2_firmware6.3.40 or later

Affected products

ProductAffected versionsFixed in
ptzoptics pt30x-sdi_firmwarev < 6.3.406.3.40
ptzoptics pt30x-ndi-xx-g2_firmwarev < 6.3.406.3.40

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.