CVE-2025-14097

High

Description

A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means. The issue is caused by a weakness in the analyzer’s application software.                                                                                                                                                                                                Other related CVE's are CVE-2025-14095 & CVE-2025-14096.                                                                                                      Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer.                                                                                                                                                                        Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.                         Permanent solution: Customers should ensure the following: • The network is secure, and access follows best practices. Local Radiometer representatives will contact all affected customers to discuss a permanent solution.                                                      Exploit Status: Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.

SeverityHigh
CVSS7.2
Exploit probability—
ProductABL90 FLEX and ABL90 FLEX PLUS Analyzers
PublishedDec 17, 2025
First seenDec 17, 2025

How to fix

Sources list no fixed version or patch link for this vulnerability.

Affected products

ProductAffected versionsFixed in
Radiometer Medical Aps ABL90 FLEX and ABL90 FLEX PLUS AnalyzersApplication software versions < 3.5MR11 with Windows 7, Windows XP operating systems—
Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX AnalyzersApplication software versions < 6.20MR2 with Windows 7, Windows XP operating systems—
Radiometer Medical Aps AQT90 FLEX AnalyzersApplication software versions <= 8.13 MR2 with Windows 7, Windows XP operating systems—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.

CVE-2025-14097 · ABL90 FLEX and ABL90 FLEX PLUS Analyzers · Dark Radar