CVE-2025-22961

High

Description

A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.

SeverityHigh
CVSS8.0
Exploit probability—
ProductMaxiva UAXT
PublishedFeb 13, 2025
First seenFeb 13, 2025

How to fix

Sources list no fixed version or patch link for this vulnerability.

Affected products

ProductAffected versionsFixed in
GatesAir Maxiva UAXTNo range specified—
GatesAir VAXT transmittersNo range specified—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management