CVE-2025-30645
Description
A NULL Pointer Dereference vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack (DS) Lite tunnel to crash the flowd process, resulting in a Denial of Service (DoS). Continuous triggering of specific control traffic will create a sustained Denial of Service (DoS) condition. On all SRX platforms, when specific, valid control traffic needs to be sent out of a DS-Lite tunnel, a segmentation fault occurs within the flowd process, resulting in a network outage until the flowd process restarts. This issue affects Junos OS on SRX Series: * All versions before 21.2R3-S9, * from 21.4 before 21.4R3-S9, * from 22.2 before 22.2R3-S5, * from 22.4 before 22.4R3-S6, * from 23.2 before 23.2R2-S3, * from 23.4 before 23.4R2.
How to fix
- juniper junos21.2 or later
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| juniper junos | v < 21.2, 21.2, 21.4, 22.2, 22.4, 23.2, 23.4 | 21.2 |
Check your version
Choose the product and enter the version you run to see whether it falls in the affected range.
Attack Surface Management
See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.