CVE-2025-9313

Critical

Description

An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data. This issue affects Asseco mMedica in versions before 11.9.5.

SeverityCritical
CVSS9.3
Exploit probability—
ProductmMedica
PublishedOct 28, 2025
First seenOct 28, 2025
Weakness typeCWE-288CWE-288

How to fix

Update
  • Asseco Poland S.A. mMedica11.9.5 or later

Affected products

ProductAffected versionsFixed in
Asseco Poland S.A. mMedicav < 11.9.511.9.5

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.