CVE-2026-100525

Medium

Description

The OpenClaw Prometheus diagnostics plugin (@openclaw/diagnostics-prometheus) before version 2026.9.3 does not enforce the operator.read scope on its authenticated metrics endpoint. In deployments using an identity-bearing Gateway authentication mode such as trusted-proxy, a caller whose effective role has no read scope can retrieve the diagnostics document even though ordinary read methods reject the same identity, disclosing operational metrics to an authenticated profile intentionally limited below read access. Shared-secret Gateway callers already hold the documented full operator scope and are not affected. The issue is fixed in 2026.9.3; as a workaround, disable the Prometheus endpoint or ensure every identity that can reach it is intended to hold operator.read.

SeverityMedium
CVSS4.3
Exploit probability—
ProductOpenclaw Diagnostics-prometheus
PublishedSep 26, 2026
First seenSep 26, 2026

How to fix

Update
  • openclaw diagnostics-prometheus2026.9.3 or later

Affected products

ProductAffected versionsFixed in
openclaw diagnostics-prometheusv < 2026.9.32026.9.3

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.