CVE-2026-103571

High

Description

An elevation of privilege vulnerability exists when the Windows Cryptography Next Generation (CNG) Key Isolation service improperly handles memory. An attacker who successfully exploited this vulnerability could run processes in an elevated context. To exploit this vulnerability, an attacker would first have to gain execution on the victim system. An attacker could then run a specially crafted application to elevate privileges. The security update addresses the vulnerability by correcting how the Windows CNG Key Isolation Service handles memory.

SeverityHigh
CVSS7.0
Exploit probability—
ProductWindows 10 Version 1607
PublishedNov 10, 2026
First seenNov 10, 2026
Weakness typeCWE-415CWE-415

How to fix

Update
  • Microsoft Windows 10 Version 160710.0.14393.9688 or later
  • Microsoft Windows 10 Version 180910.0.17763.9487 or later
  • Microsoft Windows 10 Version 21H210.0.19044.7846 or later
  • Microsoft Windows 10 Version 22H210.0.19045.7846 or later
  • Microsoft Windows 11 version 23H210.0.22631.7711 or later
  • Microsoft Windows 11 Version 23H210.0.22631.7711 or later
  • Microsoft Windows 11 Version 24H210.0.26100.9974 or later
  • Microsoft Windows 11 Version 25H210.0.26200.9974 or later
  • Microsoft Windows 11 version 26H110.0.28000.3501 or later
  • Microsoft Windows 11 Version 26H210.0.26300.9974 or later
  • Microsoft Windows Server 201610.0.14393.9688 or later
  • Microsoft Windows Server 2016 (Server Core installation)10.0.14393.9688 or later

Affected products

ProductAffected versionsFixed in
Microsoft Windows 10 Version 160710.0.14393.0 ≤ v < 10.0.14393.968810.0.14393.9688
Microsoft Windows 10 Version 180910.0.17763.0 ≤ v < 10.0.17763.948710.0.17763.9487
Microsoft Windows 10 Version 21H210.0.19044.0 ≤ v < 10.0.19044.784610.0.19044.7846
Microsoft Windows 10 Version 22H210.0.19045.0 ≤ v < 10.0.19045.784610.0.19045.7846
Microsoft Windows 11 version 23H210.0.22631.0 ≤ v < 10.0.22631.771110.0.22631.7711
Microsoft Windows 11 Version 23H210.0.22631.0 ≤ v < 10.0.22631.771110.0.22631.7711
Microsoft Windows 11 Version 24H210.0.26100.0 ≤ v < 10.0.26100.997410.0.26100.9974
Microsoft Windows 11 Version 25H210.0.26200.0 ≤ v < 10.0.26200.997410.0.26200.9974
Microsoft Windows 11 version 26H110.0.28000.0 ≤ v < 10.0.28000.350110.0.28000.3501
Microsoft Windows 11 Version 26H210.0.26300.0 ≤ v < 10.0.26300.997410.0.26300.9974
Microsoft Windows Server 201610.0.14393.0 ≤ v < 10.0.14393.968810.0.14393.9688
Microsoft Windows Server 2016 (Server Core installation)10.0.14393.0 ≤ v < 10.0.14393.968810.0.14393.9688
Microsoft Windows Server 201910.0.17763.0 ≤ v < 10.0.17763.948710.0.17763.9487
Microsoft Windows Server 2019 (Server Core installation)10.0.17763.0 ≤ v < 10.0.17763.948710.0.17763.9487
Microsoft Windows Server 202210.0.20348.0 ≤ v < 10.0.20348.587010.0.20348.5870
Microsoft Windows Server 202510.0.26100.0 ≤ v < 10.0.26100.3382210.0.26100.33822
Microsoft Windows Server 2025 (Server Core installation)10.0.26100.0 ≤ v < 10.0.26100.3382210.0.26100.33822

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.