CVE-2026-33892

High

Description

A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device. Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.

SeverityHigh
CVSS7.1
Exploit probability—
ProductIndustrial Edge Management Pro V1
PublishedApr 14, 2026
First seenApr 14, 2026
Weakness typeCWE-305CWE-305

How to fix

Update
  • Siemens Industrial Edge Management Pro V1V1.15.17 or later
  • Siemens Industrial Edge Management Pro V2V2.1.1 or later
  • Siemens Industrial Edge Management VirtualV2.8.0 or later

Affected products

ProductAffected versionsFixed in
Siemens Industrial Edge Management Pro V1V1.7.6 ≤ v < V1.15.17V1.15.17
Siemens Industrial Edge Management Pro V2V2.0.0 ≤ v < V2.1.1V2.1.1
Siemens Industrial Edge Management VirtualV2.2.0 ≤ v < V2.8.0V2.8.0

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.