CVE-2026-45681
Description
OpenTelemetry eBPF Instrumentation provides eBPF instrumentation based on the OpenTelemetry standard. Prior to version 0.9.0, the per-CPU message-buffer fallback path uses a 256-byte backup buffer but preserves the original payload size, which can be up to 8KB. If a CPU mismatch occurs, OBI can read beyond the fallback buffer and leak adjacent memory into telemetry. This issue has been patched in version 0.9.0.
How to fix
- opentelemetry ebpf_instrumentation0.9.0 or later
- go.opentelemetry.io/obi0.9.0 or later
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| opentelemetry ebpf_instrumentation | v < 0.9.0 | 0.9.0 |
| go.opentelemetry.io/obiGo | v < 0.9.0 | 0.9.0 |
Check your version
Choose the product and enter the version you run to see whether it falls in the affected range.
Attack Surface Management