CVE-2026-4638
Description
PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter. Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.
How to fix
- Paessler GmbH PRTG Network Monitor26.2.120.1449 or later
Affected products
| Product | Affected versions | Fixed in |
|---|---|---|
| Paessler GmbH PRTG Network Monitor | v < 26.2.120.1449 | 26.2.120.1449 |