CVE-2026-58115

Critical

Description

A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4.1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.

SeverityCritical
CVSS10.0
Exploit probability—
ProductSIMATIC IoT2050 Advanced
PublishedAug 11, 2026
First seenAug 11, 2026

How to fix

Update
  • Siemens SIMATIC IoT2050 AdvancedV4.3.4.1 or later

Affected products

ProductAffected versionsFixed in
Siemens SIMATIC IoT2050 Advancedv < V4.3.4.1V4.3.4.1

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.

CVE-2026-58115 · SIMATIC IoT2050 Advanced · Dark Radar