CVE-2026-72895

High

Description

A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device.

SeverityHigh
CVSS7.7
Exploit probability—
ProductSIMATIC IPC BX-21A
PublishedOct 13, 2026
First seenOct 13, 2026
Weakness typeCWE-1394CWE-1394

How to fix

Update
  • Siemens SIMATIC IPC BX-21AV31.01.13 or later
  • Siemens SIMATIC IPC RW-543AV1.1.4 or later
  • Siemens SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377GV28.01.15 or later

Affected products

ProductAffected versionsFixed in
Siemens SIMATIC IPC BX-21Av < V31.01.13V31.01.13
Siemens SIMATIC IPC RW-543Av < V1.1.4V1.1.4
Siemens SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377Gv < V28.01.15V28.01.15

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.