CVE-2026-73173

High

Description

Nozomi Networks Labs identified a CWE-306: Missing Authentication for Critical Function vulnerability in the edgserver management protocol of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote unauthenticated attacker to invoke critical device-management functions, including network reconfiguration, reboot, reset, and firmware upgrade, by sending crafted requests to TCP port 5058.

SeverityHigh
CVSS8.8
Exploit probability—
ProductEKI-1242EIMS
PublishedSep 16, 2026
First seenSep 16, 2026

How to fix

Affected products

ProductAffected versionsFixed in
Advantech EKI-1242EIMSv ≤ 1.06.01—
Advantech EKI-1242IEIMSv ≤ 1.06.01—

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.

CVE-2026-73173 · EKI-1242EIMS · Dark Radar