CVE-2026-80156

Critical

Description

Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device's filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.

SeverityCritical
CVSS9.1
Exploit probability—
ProductSLC8000
PublishedSep 22, 2026
First seenSep 22, 2026

How to fix

Update
  • LANTRONIX SLC80009.7.0.5 or later
  • LANTRONIX EMG85009.7.0.1 or later
  • LANTRONIX EMG75009.7.0.1 or later
  • LANTRONIX SLC90009.7.0.2 or later

Affected products

ProductAffected versionsFixed in
LANTRONIX SLC8000v < 9.7.0.59.7.0.5
LANTRONIX EMG8500v < 9.7.0.19.7.0.1
LANTRONIX EMG7500v < 9.7.0.19.7.0.1
LANTRONIX SLB882No range specified—
LANTRONIX SLCx-03No range specified—
LANTRONIX SLCx-02No range specified—
LANTRONIX SLC9000v < 9.7.0.29.7.0.2

Check your version

Choose the product and enter the version you run to see whether it falls in the affected range.

In the Intelligence 360 plan

Attack Surface Management

See the assets tied to your domains, the technologies they run and known vulnerabilities in one list.